Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Rev. Col. Bras. Cir ; 44(1): 102-106, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-842641

ABSTRACT

ABSTRACT The clinical definition of cardiogenic shock is that of a low cardiac output and evidence of tissue hypoxia in the presence of adequate blood volume. Cardiogenic shock is the main cause of death related to acute myocardial infarction (AMI), with a mortality rate of 45-70% in the absence of aggressive and highly specialized technical care. The intra-aortic balloon pump (IABP) is one of the most widely used mechanical assisting devices. During the last two decades, about 42% of patients with AMI who evolved with cardiogenic shock received mechanical circulatory assistance with IABP. Its clinical indication has been based on non-randomized studies and registry data. Recent studies have shown that the use of IABP did not reduce 30-day mortality in patients with AMI and cardiogenic shock treated with the strategy of early myocardial revascularization as the planned primary objective. The guidelines of the American Heart Association and of the European Society of Cardiology have reassessed their recommendations based on the results of meta-analyzes, including the IABP-SCHOCK II Trial study, which did not evidence an increase in survival of patients who received mechanical support with IABP. This review article addresses the clinical impact of IABP use in the cardiogenic shock caused by AMI.


RESUMO A definição clínica de choque cardiogênico é a de um quadro de baixo débito cardíaco e evidência de hipóxia tecidual, na presença de volemia adequada. O choque cardiogênico representa a principal causa de óbito relacionada ao infarto agudo do miocárdio (IAM), com índice de mortalidade em torno de 45% a 70%, na ausência de cuidados técnicos agressivos e altamente especializados. O balão intra-aórtico (BIA) é um dos dispositivos de assistência mecânica mais utilizados no mundo. Nas duas últimas décadas, cerca de 42% dos pacientes com IAM, que evoluíram com choque cardiogênico, receberam assistência circulatória mecânica com BIA. Sua indicação clínica tem sido baseada em estudos não randomizados e dados de registro. Estudos recentes têm demonstrado que o uso do BIA não reduziu a mortalidade hospitalar (30 dias) em pacientes com IAM e choque cardiogênico, tratados com a estratégia de revascularização precoce do miocárdio como objetivo primário planejado. As diretrizes da Associação Americana de Cardiologia e da Sociedade Europeia de Cardiologia reavaliaram suas recomendações, baseadas nos resultados de metanálises, incluindo o estudo IABP-SCHOCK II Trial, que não evidenciou aumento na sobrevida de pacientes que receberam suporte mecânico com BIA. Este artigo de revisão aborda o impacto clínico do uso do BIA no choque cardiogênico ocasionado pelo IAM.


Subject(s)
Humans , Shock, Cardiogenic/surgery , Intra-Aortic Balloon Pumping
3.
Rev. méd. Minas Gerais ; 21(3)jul.-set. 2011.
Article in Portuguese | LILACS-Express | LILACS | ID: lil-621140

ABSTRACT

O infarto do ventrículo direito (VD) não é entidade clínica rara. É observado em 10 a 50% dos pacientes com infarto da parede inferior do ventrículo esquerdo (VE). Estão agrupados nesse amplo espectro diagnóstico os pacientes com disfunção ventricular leve, assintomáticos e aqueles em choque cardiogênico. O reconhecimento do infarto do VD é importante, porque se associa a mais morbi e mortalidade imediatas, além de apresentar prioridade de tratamento específico. O diagnóstico do infarto do VD é baseado em sinais clínicos, eletrocardiográficos, hemodinâmicos e ecográficos. A abordagem adequada do infarto do VD inclui medidas para manter a pré-carga adequada e reduzir a pós-carga do VD, suporte inotrópico, e manutenção do sincronismo átrio-ventricular. A terapia de reperfusão miocárdica com fibrinolítico ou a angioplastia primária deve ser indicada e iniciada precocemente. A maior parte dos pacientes que sobrevivem ao infarto do VD tem resolução completa das alterações hemodinâmicas com o restabelecimento da função do VD no decorrer de semanas a meses, sugerindo que ?atordoamento? do miocárdio direito, em vez de necrose irreversível, ocorre com mais frequência.


Right ventricle infarction (RVI) is not a rare clinical entity. It complicates 10 to 50% of patients with inferior wall myocardial infarctions. Under the term RVI we can find mild, asymptomatic dysfunction of right ventricle and cardiogenic shock as well. Recognition of the syndrome of RVI is important as it is associated with considerable immediate morbidity and mortality and has a well-delineated set of priorities for its management. Diagnosis is based on clinical signs, electrocardiographic findings, hemodynamic measurements and echographic evaluations. The proper management of RVI includes volume loading to maintain adequate right ventricular preload, ionotropic support, reduction of right ventricular afterload and maintenance of atrioventricular synchrony. Early reperfusion with fibrinolytic therapy or direct angioplasty should be initiated at the earliest signs of right ventricular dysfunction. Most patients who survive RVI have complete resolution of hemodynamic abnormalities with restoration of proper right ventricle function over a period of weeks to months, suggesting right ventricular stunning rather than irreversible necrosis has occurred.

4.
Rev. Assoc. Med. Bras. (1992) ; 57(2): 187-193, mar.-abr. 2011. tab
Article in Portuguese | LILACS | ID: lil-584071

ABSTRACT

OBJETIVO: Avaliar a prevalência de estenose hemodinamicamente significativa na revascularização infrainguinal realizada com a veia safena magna reversa. MÉTODOS: No período compreendido entre março de 2008 e março de 2009, foram realizadas 56 revascularizações infrainguinais com a veia safena magna reversa em 56 pacientes, dos quais 32 foram avaliados com ultrassonografia vascular no 30º dia de pós- operatório. Foi analisada a prevalência de estenoses significativas nos enxertos e sua relação com as características clínico-cirúrgicas dos pacientes. Os parâmetros avaliados foram a localização das estenoses ao longo do enxerto, fatores de risco associados e a relação existente entre a ultrassonografia vascular e o índice tornozelo-braço no diagnóstico de estenoses. RESULTADOS: Houve prevalência de 48,4 por cento de estenoses significativas nos enxertos avaliados, com 19,4 por cento de estenoses graves e 29 por cento de estenoses leve a moderada. Não foram encontradas associações significativas entre sexo, diabetes mellitus, hipertensão arterial, hipercolesterolemia, diâmetro do enxerto, localização da anastomose distal, composição do enxerto e a constatação de estenoses significativas. Observou-se fraca correlação entre os métodos no diagnóstico das estenoses em geral (K = 0,30; IC95 por cento 0,232-0,473; p = 0,018), mas razoável concordância no diagnóstico das estenoses graves (K = 0,75; IC95 por cento 0,655-0,811; p = 0,0001). CONCLUSÃO: Este estudo demonstrou elevada prevalência de estenoses no 30º dia do pós-operatório, com localização predominante na metade proximal do enxerto. O índice tornozelo-braço e a ultrassonografia vascular apresentaram concordância, sobretudo no diagnóstico das estenoses graves, mas o índice tornozelo-braço, isoladamente, mostrou-se insuficiente na vigilância dos enxertos de veia safena magna reversa.


OBJECTIVE: The aim of this study was to evaluate the prevalence of hemodynamically significant infrainguinal bypasses stenosis using reverse great saphenous vein graft. METHODS: From March of 2008 to March of 2009, 56 infrainguinal bypasses were performed with reverse great saphenous vein graft in 56 patients. On the 30th post-operative day, 32 out of 56 patients were submitted to vascular ultrasonography. The prevalence of significant graft stenosis was determined. In addition, the diagnosis of stenosis was related to the clinical and surgical characteristics of the patients. The variables analyzed at the moment of diagnosis were the localization of the graft stenosis, the risk factors associated with stenosis and the association of vascular ultrasonography findings with ankle brachial pressure index (ABI). RESULTS: The overall prevalence of significant graft stenosis was 48.4 percent. Out of the total number of observed stenosis, 19.4 percent were considered severe, and 29 percent mild or moderate. There was no significant association between the presence of significant stenosis and the following variables: gender, diabetes, hypertension, smoking, hipercholesterolemia, graft diameter, site of the distal anastomosis, and graft composition. There was a weak agreement between ABI and vascular ultrasonography in detecting stenosis in general (K = 0.30; CL95 percent 0.232 - 0.473; p = 0.018). However, there was a substantial agreement in detecting severe stenosis (K = 0.75; CL95 percent 0.655 - 0.811; p = 0.0001). CONCLUSION: There was a high prevalence of stenosis on the 30th post-operative day, mostly localized in the proximal half of the vein graft. There was no significant association of stenosis with clinical and surgical factors analyzed. ABI and vascular ultrasonography had weak agreement with the diagnosis of stenosis in general and an important agreement for the diagnosis of severe stenosis.


Subject(s)
Female , Humans , Male , Constriction, Pathologic/etiology , Graft Occlusion, Vascular/epidemiology , Saphenous Vein/transplantation , Ankle Brachial Index , Arteries , Constriction, Pathologic/epidemiology , Constriction, Pathologic , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular , Prevalence , Risk Factors , Saphenous Vein , Ultrasonography, Doppler, Duplex
6.
Rev. bras. cir. cardiovasc ; 22(1): 41-48, jan.-mar. 2007. ilus, graf
Article in Portuguese | LILACS, SES-SP | ID: lil-454626

ABSTRACT

OBJETIVO: A Síndrome de Hipoplasia de Câmaras Esquerdas representa um grande desafio para cirurgiões do mundo inteiro. Atualmente, tem sido proposto procedimento paliativo alternativo, por meio da bandagem bilateral das artérias pulmonares associada à colocação de stent no canal arterial e atrioseptostomia. No entanto, as bandagens utilizadas são fixas, podendo tornar-se inadequadas após o fechamento do esterno ou com o rápido crescimento somático do paciente. Descrevemos a primeira aplicação clínica do novo dispositivo miniaturizado de bandagem ajustável das artérias pulmonares em neonato portador da síndrome de hipoplasia de câmaras esquerdas, o qual permitiu ajustes percutâneos precisos do fluxo sangüíneo pulmonar. MÉTODO: Através de esternotomia mediana, neonato de 5 dias de vida foi submetido à bandagem pulmonar bilateral, usando este novo dispositivo, combinada com interposição de tubo de PTFE entre o tronco pulmonar e o tronco braquiocefálico. RESULTADOS: O paciente apresentou boa evolução pós-operatória. Três ajustes percutâneos das bandagens foram necessários para manter a saturação arterial de oxigênio entre 75-85 por cento. No 48° dia de vida, o paciente foi submetido a atrioseptostomia com colocação de stent (6 mm) para tratamento de comunicação interatrial restritiva. No 106° dia de vida, realizou-se operação de Norwood associada à anastomose cavopulmonar bilateral. As bandagens foram removidas, sem distorção das artérias pulmonares. CONCLUSÕES: O uso clínico deste sistema inovador de bandagem ajustável das artérias pulmonares mostrou-se factível, seguro e eficaz. Permitiu o ajuste fino do fluxo pulmonar de acordo com as necessidades clínicas, proporcionando um equilíbrio preciso entre as circulações pulmonar e sistêmica.


OBJECTIVE: Hypoplastic left heart syndrome remains a challenge for worldwide surgeons. Initial palliation employing bilateral pulmonary artery banding along with ductal stent implantation and atrial septostomy has been proposed as an alternative approach. However, the surgically placed bands are fixed and may become inadequate after sternum closure or with somatic growth of the patient. We describe the first case in which a neonate with hypoplastic left heart syndrome was initially managed using a mini banding system that allows for fine percutaneous adjustments of pulmonary blood flow. METHOD: Through a mid sternotomy, a 5 day-old neonate underwent bilateral pulmonary artery banding using this new system combined with placement of a main pulmonary artery to innominate artery shunt. RESULTS: The patient had an uneventful postoperative course. Three percutaneous adjustments of the banding system were necessary to keep the arterial oxygen saturation in the 75 percent-85 percent range. On the 48th day of life, she was submitted to stent placement (6 mm) within the atrial septum to treat a restrictive atrial septal defect. The Norwood operation and the bidirectional Glenn shunt were carried out on the 106th day of life. The bands were removed with no distortion of the pulmonary arteries. CONCLUSIONS: The clinical use of this innovative pulmonary artery banding system was feasible, safe and effective. It allowed for customization of the pulmonary blood flow according to the underlying clinical needs, resulting in a more precise balance between the pulmonary and systemic circulations.


Subject(s)
Female , Humans , Infant, Newborn , Cardiac Surgical Procedures/instrumentation , Hypoplastic Left Heart Syndrome/surgery , Pulmonary Artery/surgery , Hypoplastic Left Heart Syndrome/physiopathology , Palliative Care , Pulmonary Circulation
7.
São Paulo; s.n; 2007. [112] p. ilus, tab.
Thesis in Portuguese | LILACS | ID: lil-586973

ABSTRACT

Os modelos experimentais de falência do ventrículo direito (VD) descritos são de difícil execução, por envolverem procedimentos cirúrgicos complexos e dispendiosos, com alta mortalidade e baixa reprodutividade. Também são raros aqueles que promovem falência ventricular exclusiva do ventrículo direito. Com o objetivo de simular a situação clínica de falência ventricular exclusiva do VD, desenvolvemos um modelo experimental de falência crônica isolada do VD, feito através da injeção de etanol intramiocárdico. A disfunção do VD foi induzida em treze cães adultos, através de múltiplas injeções de etanol a 96% (dose total 1ml/kg), na via de entrada e na porção trabecular do VD. Foram analisados parâmetros hemodinâmicos, metabólicos e ecocardiográficos, em condições basais e após indução da falência. Os animais foram mantidos vivos por um período de 14 dias, após o qual foram reoperados e mortos para análise morfológica dos corações. As pressões foram aferidas na artéria femoral, átrio esquerdo (AE), átrio direito (AD), tronco pulmonar (TP) e VD. O fluxo sanguíneo foi medido na aorta e no tronco pulmonar. Na primeira operação, os dados hemodinâmicos foram registrados antes e imediatamente após a indução da falência do VD. Estes parâmetros também foram coletados na reoperação (14 dias pós-indução da falência). Amostras de sangue arterial e venoso foram colhidas simultaneamente ao registro dos parâmetros hemodinâmicos para avaliação dos gases sanguíneos e dosagem de lactato. Foram feitas avaliações ecocardiográficas no pré-operatório, no sexto e no 130 dia pós-operatório (PO). Houve uma mortalidade de 15,4% (2/13). Observou-se uma queda significativa no débito cardíaco pulmonar após a indução da falência e na reoperação (14º PO), quando comparado aos valores medidos no momento basal (p=0,002). Esta queda do desempenho ventricular direito ocasionou um aumento nos valores do lactato venoso, quando comparados os valores basais contra aqueles do pós infusão...


Isolated chronic right ventricle (RV) dysfunction is difficult to achieve in experimental models, and sometimes very expensive. Some models require complex surgical procedures, with a high mortality rate and low reproducibility. In order to simulate the clinical status of RV failure, we have developed an experimental model of chronic RV failure by injecting local intramyocardial ethanol 96%. A severe RV dysfunction was induced in 13 mongrel dogs by means of multiple intramyocardial injections of ethanol 96% (total dose of 1ml/kg), in the inlet and trabecular portions of the RV. The hemodynamics, metabolic and ecocardiografic parameters were evaluated at baseline condition and after RV failure. The animals were followed for a 14-day period. After that, they were reoperated for pressure measurements, taken from femoral artery, left atrium (LA), right atrium (RA), RV and main pulmonary artery (PA). Blood flow was measured in the aorta (AO) and PA. Metabolic parameters were assessed simultaneously to pressure measurements, with arterial and venous blood samples withdrawn for gas and lactate analysis, and then, they were killed for morphological evaluation of the heart. All the animals were submitted to echocardiographic evaluation before the first operation, on sixth and on de 13th postoperative day. The mortality rate was 15,4% (2/13). There was a significant decrease in the pulmonary blood flow after RV failure induction (p=0,0018), as well as in the reoperation (p=0,002), as compared to baseline. This decrease in RV performance caused an increase in the venous lactate level, when baseline values are compared with pos infarction values (p=0,001) and reoperation (p=0003). The echocardiografic findings revealed an increased RV diastolic volume on the 6th (p=0,0001) and 13th postoperative day (p=0,0084), as compared to baseline values. Conversely, there was a significant decrease in the RV ejection fraction on the 6th and 13th postoperative day, when compared...


Subject(s)
Animals , Male , Dogs , Heart Failure , Myocardial Ischemia/chemically induced , Models, Animal , Ventricular Dysfunction, Right
SELECTION OF CITATIONS
SEARCH DETAIL